(844) 533-7230
Welcome to LEDRADIANT, your LED lighting source

Shopping Cart - 0 Item

You have no items in your shopping cart.

 

  • 700 Watt hid Replacement for this 150W LED retrofit kit 6000K
  • 700 Watt hid Replacement for this 150W LED retrofit kit 6000K

150W LED Lamp Bulb Retrofit, 5700K, IP40, E39, UL.

Availability: In stock


Our 150 Watt LED Retrofit Kit is ideal to replace a bulb up to 750 watt HID. It saves you up to 75% in electricity and hundreds in unnecessary bulb replacements. Its Lifespan is over 15 years. LEDRADIANT Retrofit kits are IP40,. Estimated annual ROI is about 40%. UL listed.

Click here to see other Retrofit Kit.

Availability: In stock




Replace halogen, Metal Halide or HPS with LED Retrofit Kits
LED Retrofit Kits will be equivalent about 5 times Metal Halide or HPS
HPS Metal Halide LED Retrofit Kit
250W 250W  60Watts
350W 300W  80 Watts
400W 400W  120 Watts
600W 500W  150 Watts
800W 600W  240 Watts
1000W 800W  320 Watts
1000W 1000W  320 Watts
No
LED RETROFIT KITS APPLICATIONS AND WIRING

LED RETROFIT KITS:

Looking to retrofit your metal halide fixtures? These LED engines are the perfect solution!

Model Numbers:

60W: RES-RAN-60630-CD
80W: RMS-RAN-80840-CD
100W: RMS-RAN-1J10E-CD
120W: RMS-RAN-1B12F-CD
150W: RMS-RAN-1E15G-CD
240W: RMS-RAN-2D25B-CD

480V:

120W: RMS-RHN-1B13I-6D
150W: RMS-RHN-1E17F-CD
200W: RMS-RHN-2J20G-6D
300W: RMS-RHN-3J34F-6D
450W: RMS-RHN-4E48A-6D

Equivalent HPS/MH:
The RMS-RAN and RMS-RHN series products are the ideal retrofit for Parking Lots, Shoe Boxes, Street lights, Flood Lights, Wall Packs, High Bays and Canopies. The smart rotatable bracket makes these LED Retrofit kits easy and fast replacements for HPS/MH bulbs from 150W to 1000W.

INSTALLATION PROFILE:
* WARNING * READ ALL INSTRUCTIONS BEFORE INSTALLATION

* W A R N I N G *- TURN OFF ALL POWER TO THE FIXTURE BEFORE INSTALLATION.
* W A R N I N G *- Risk of fire or electric shock: LED Retrofit Kit Installation requires knowledge of electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
* W A R N I N G *- Risk of fire or electric shock: Install this KIT only in the luminaries that have the construction features and dimensions shown in the photographs and / or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
* W A R N I N G *- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
* NOTES *
  • For longest life and heat dissipation: PERMANENTLY REMOVE THE FIXTURE’S REFLECTOR. Retrofit warranty will be voided if the fixture’s reflector has not been removed. Removing the reflector provides extra air capacity that is used to keep the LED head and driver cool.
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
  • Disconnect existing wires from lamp holder terminals or cut existing lamp holder leads away from the lamp holder and properly isolate wires that might be live when the fixture is powered. The lamp holder is only used for mechanical purposes. Employ safe applicable connectors to all connections.
  • Never take the retrofit apart. Never touch the LEDs, LEDs life will shorten and warranty will be void.
  • Be sure nothing will touch or fall into the fan blades after the fixture is mounted.
  • A protection plate must be installed covering the driver to avoid touching the wires and/or connections.
  • The minimum room space in the existing fixture to avoid overheating is 5" * 5" * 2.5".

SHOE BOXES and FLOOD LIGHTS:
  • Remove existing ballast, bulb and reflector. Leave no electrical connections to the E26/E39 base.
  • Fix the LED driver onto the mounting plate. (see pictures below)
  • Although we provide a mogul base for convenience in holding the Retrofit kit, if you are applying for rebates, do not use it, instead use just the bracket, otherwise the installation will not pass DLC inspection.
  • Connect the driver's output wires to the retrofit kit. Make sure the fan blades will not be obstructed.

* NOTES *
  • You may customize the mounting plate or bracket so it will mount into the fixture’s existing screw posts.
    Avoid drilling through holes that could allow water in, the retrofit kits are not water resistant.
  • A protection plate must be installed to cover the driver to isolate it from wires and connections.





WALL PACKS and CANOPIES:
  • Remove existing ballast, bulb and reflector. Leave no electrical connections to the E26/E39 base.
  • Fix the LED driver onto the mounting plate. (See pictures below). Avoid drilling thru holes that could allow water in, the retrofit kits are not water resistant.
  • Although we provide a mogul base for convenience in holding the Retrofit kit, if you are applying for rebates, do not use it, instead use just the bracket, otherwise the installation will not pass DLC inspection.
  • Connect the driver's output wires to the retrofit kit. Make sure that nothing will obstruct the fan blades.

* NOTES *
  • You may customize the mounting plate or bracket so it can be mounted into the fixture’s existing screw posts.
  • A plate to cover the driver to avoid touching the wires connections is needed.







STREET LIGHTS:
  • Remove existing ballast, bulb and reflector. Leave no electrical connections to the E26/E39 base.
  • Mount the LED driver in place of the ballast.
  • Fix the retrofit kit with the bracket, then adjust the retrofit head angle and position so that it provides the best lighting.
  • Connect the driver's output wires to the retrofit kit. Make sure that nothing will obstruct the fan blades.

Tip: The original mogul base was attached to the reflector when it was removed, customized plate is easy to install.




HIGH BAYS:
  • Remove existing ballast and bulb. Leave no electrical connections to the E26/E39 base.
  • Mount the LED driver in place of the ballast.
  • Although we provide a mogul base for convenience in holding the Retrofit kit, if you are applying for rebates, do not use it, instead use just the bracket, otherwise the installation will not pass DLC inspection.
  • Make sure nothing will obstruct the fan blades.

Tip: You may customize the mounting plate or bracket to mount the driver if needed.


* WARNING *
  • The unit is designed for several years use with minimum care. For Optimum performance, periodically clean the reflector and lens with a mild, non-abrasive, glass cleaner and a soft cloth. DO NOT use solvents or cleaners containing abrasive agents. When cleaning the fixture, make sure you have the power turned off and do not spray liquid cleaner directly onto the LED, socket or wiring.
  • Retrofit kits 180W and over require a lens cover, pictured below



180W-240W PC lens cover dimension:


300W-450W PC cover lens dimension:



5 YEAR WARRANTY POLICY
For Commercial LED Lamps and fixtures


This document sets forth the warranty policy of the LEDRadiant organization (‘LEDRadiant’) from which you (‘Purchaser’) purchase your commercial LED Lamps .

This policy is applicable only to LEDRadiant (‘Products’) described in the Warranty Certificate extended to the Purchaser along with the correlated invoice or the Certificate in the website page for the product being questioned.

This warranty policy is subject to the provisions as set forth herein and is subject to the terms and conditions as attached to this document (‘Warranty Terms and Conditions’) .

This warranty policy only applies if referred to in a sales agreement between LEDRadiant and the Purchaser and it will replace the standard warranty clause provided in the LEDRadiant general terms and conditions of sale.

Warranty period
5 Year. The warranty period starts on the date the products are delivered.
By default, purchaser receives above mentioned ‘standard warranty’.

On request, an ‘extended warranty’ or ‘customized project warranty’ can be agreed upon after evaluation of the specific application conditions. Extended warranty cost will be calculated and applied to the order.

Purchaser shall not rely upon any other information or documentation.

Within the warranty period, LEDRadiant will replace any defective bulb or fixture with equal or updated working model in the same conditions or better.

Summary Warranty Terms and Conditions (non-exhaustive)

This warranty policy is valid only for products sold in The United States of America.
Products have been purchased directly from a LEDRadiant (sales) organization.
Proof of purchase is available for inspection by LEDRadiant.
Products have been properly installed and operated in accordance with the manufacturer’s instructions.
• More than 10% of the LED chips are not properly working.
A LEDRadiant representative will have access to the defective Products.
If the Products or other parts become suspect, the representative shall have the right to invite other manufacturers’ representatives to evaluate the lighting systems.
Shipping and Labor costs for installation of the Products are not covered under this warranty.

This warranty is valid for order number:




By LEDRadiant

Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

RETROFITING UL LUMINAIRES
ONLINE CERTIFICATIONS DIRECTORY
IFAR.Guidelnfo
Light-emitting-diode Retrofit Luminaire Conversion Kits
[Luminaires and Fittings] Light-emitting-diode Retrofit Luminaire Conversion Kits

GENERAL

This category covers light-emitting-diode (LED) retrofit kits intended for field installation in certified luminaires and office-furnishing lights.

This category does not cover retrofit reflector kits and luminaire conversion lamps intended for direct replacement of existing lamps without the need for modification, rewiring or component replacement in the luminaire.

The retrofit kits consist of LED light sources, installation instructions, subassemblies, luminaire marking labels, and assembly aids (where appropriate) to facilitate the replacement of the existing light source in complete luminaires. The retrofit installation may require modifications to the luminaire in accordance with the installation instructions provided with the retrofit kits.

The LED retrofit kits have been investigated to determine that, when installed in accordance with the manufacturer's instructions, they do not adversely affect the operation of the luminaire. A luminaire that is modified so it can no longer accept the original lamp has a label provided by the retrofit kit manufacturer affixed to the luminaire where visible during relamping that indicates the luminaire has been modified and can no longer operate the originally-intended lamp(s).

LUMINAIRE MARKINGS

LED retrofit luminaire conversion kits that permit the insertion of the original lamp types are provided with a marking for installation by the kit installer on the retrofitted luminaire. This marking is visible during relamping and states, "This luminaire has been modified and can no longer operate the originally intended lamp," and additionally identifies the replacement LED lamp type/model to be used, together with the manufacturer's name and ordering information.

LED retrofit luminaire conversion kits using linear tubular LED lamp conversions are provided with a marking for installation by the kit installer visible during relamping that indicates in text or wiring diagram how the supply connections are made to the lampholders.

RELATED PRODUCTS

Retrofit reflector kits intended for installation on fluorescent luminaires are covered under Luminaire Conversions, Retrofit (IEUO).

Retrofit devices used to convert incandescent exit luminaires to fluorescent exit luminaires are covered under Exit Sign Conversion Kits (FWCF). LED light sources intended to replace fluorescent lamps where it is not necessary to modify the luminaire are covered under Lamps, Self-ballasted, Light-emitting-diode Type (OOLV).

ADDITIONAL INFORMATION

For additional information, see Luminaires and Fittings (HYXT) and Electrical Equipment for Use in Ordinary Locations (AALZ).

REQUIREMENTS

The basic requirements used to investigate products in this category are contained in UL Subject 1598C, "Outline of Investigation for Light-Emitting Diode (LED) Retrofit Luminaire Conversion Kits," in addition to ANSIIUL 1598, "Luminaires," ANSIIUL 153, "Portable Electric Luminaires," and/or ANSIIUL 1286, "Office Furnishings."

UL MARK

The Certification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number.

Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

RETROFITING UL LUMINAIRES

Additional Certification Markings

Products covered under this category are additionally marked with the following information:

LED RETROFIT LUMINAIRE CONVERSION


FOR USE ONLY WITH ( +)

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT

( +) PERMANENTLY CONNECTED LUMINAIRES, FLUORESCENT LUMINAIRES, INCANDESCENT LUMINAIRES, HID LUMINAIRES, OFFICE-FURNISHING LIGHTS and/or PORTABLE LUMINAIRES; or indicate the specific luminaire model(s) and luminaire manufacturer(s)

or

LED RETROFIT LUMINAIRE CONVERSION

FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT Alternate UL Mark

The Classification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Classification and Follow-Up Service. The Classification Mark for these products includes the UL symbol, the word "CLASSIFIED" above the UL symbol (as illustrated in the Introduction of this Directory), and the following additional information:

LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH ( +)

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT
Control No.

( +) PERMANENTLY-CONNECTED LUMINAIRES, FLUORESCENT LUMINAIRES, INCANDESCENT LUMINAIRES, HID LUMINAIRES, OFFICE-FURNISHING LIGHTS and/or PORTABLE LUMINAIRES; or indicate the specific luminaire model(s) and luminaire manufacturer(s)

or

LED RETROFIT LUMINAIRE CONVERSION

FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT
Control No.

* * * * * * * * * * * * * * * * * * * * * * * * *

UL, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental or consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Guide Information.

Last Updated on 2013-05-16

© 2014 UL LLC

When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " © 2014 UL LLC".

Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Customer Reviews

As always, these retrofits provide the necessary light while saving hundreds of dollars over new fixtures including installation. Review by Timothy J.
Rate
These retrofits produce an increase in the visible light over a 400 watt MH. They also cost less than new LED fixtures. Additionally, they cost less to have installed than a new LED fixture. Overall they save around $200 in comparison to a new LED fixture.
(Posted on 8/16/2017)
BRIGHT Review by JOHN M.
Rate
Very easy to install, and puts out some major light
(Posted on 4/24/2015)

Write Your Own Review

Only registered users can write reviews. Please, log in or register

Product Description



Replace halogen, Metal Halide or HPS with LED Retrofit Kits
LED Retrofit Kits will be equivalent about 5 times Metal Halide or HPS
HPS Metal Halide LED Retrofit Kit
250W 250W  60Watts
350W 300W  80 Watts
400W 400W  120 Watts
600W 500W  150 Watts
800W 600W  240 Watts
1000W 800W  320 Watts
1000W 1000W  320 Watts
Additional Information
No
LED RETROFIT KITS APPLICATIONS AND WIRING

LED RETROFIT KITS:

Looking to retrofit your metal halide fixtures? These LED engines are the perfect solution!

Model Numbers:

60W: RES-RAN-60630-CD
80W: RMS-RAN-80840-CD
100W: RMS-RAN-1J10E-CD
120W: RMS-RAN-1B12F-CD
150W: RMS-RAN-1E15G-CD
240W: RMS-RAN-2D25B-CD

480V:

120W: RMS-RHN-1B13I-6D
150W: RMS-RHN-1E17F-CD
200W: RMS-RHN-2J20G-6D
300W: RMS-RHN-3J34F-6D
450W: RMS-RHN-4E48A-6D

Equivalent HPS/MH:
The RMS-RAN and RMS-RHN series products are the ideal retrofit for Parking Lots, Shoe Boxes, Street lights, Flood Lights, Wall Packs, High Bays and Canopies. The smart rotatable bracket makes these LED Retrofit kits easy and fast replacements for HPS/MH bulbs from 150W to 1000W.

INSTALLATION PROFILE:
* WARNING * READ ALL INSTRUCTIONS BEFORE INSTALLATION

* W A R N I N G *- TURN OFF ALL POWER TO THE FIXTURE BEFORE INSTALLATION.
* W A R N I N G *- Risk of fire or electric shock: LED Retrofit Kit Installation requires knowledge of electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
* W A R N I N G *- Risk of fire or electric shock: Install this KIT only in the luminaries that have the construction features and dimensions shown in the photographs and / or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
* W A R N I N G *- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
* NOTES *
  • For longest life and heat dissipation: PERMANENTLY REMOVE THE FIXTURE’S REFLECTOR. Retrofit warranty will be voided if the fixture’s reflector has not been removed. Removing the reflector provides extra air capacity that is used to keep the LED head and driver cool.
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
  • Disconnect existing wires from lamp holder terminals or cut existing lamp holder leads away from the lamp holder and properly isolate wires that might be live when the fixture is powered. The lamp holder is only used for mechanical purposes. Employ safe applicable connectors to all connections.
  • Never take the retrofit apart. Never touch the LEDs, LEDs life will shorten and warranty will be void.
  • Be sure nothing will touch or fall into the fan blades after the fixture is mounted.
  • A protection plate must be installed covering the driver to avoid touching the wires and/or connections.
  • The minimum room space in the existing fixture to avoid overheating is 5" * 5" * 2.5".

SHOE BOXES and FLOOD LIGHTS:
  • Remove existing ballast, bulb and reflector. Leave no electrical connections to the E26/E39 base.
  • Fix the LED driver onto the mounting plate. (see pictures below)
  • Although we provide a mogul base for convenience in holding the Retrofit kit, if you are applying for rebates, do not use it, instead use just the bracket, otherwise the installation will not pass DLC inspection.
  • Connect the driver's output wires to the retrofit kit. Make sure the fan blades will not be obstructed.

* NOTES *
  • You may customize the mounting plate or bracket so it will mount into the fixture’s existing screw posts.
    Avoid drilling through holes that could allow water in, the retrofit kits are not water resistant.
  • A protection plate must be installed to cover the driver to isolate it from wires and connections.





WALL PACKS and CANOPIES:
  • Remove existing ballast, bulb and reflector. Leave no electrical connections to the E26/E39 base.
  • Fix the LED driver onto the mounting plate. (See pictures below). Avoid drilling thru holes that could allow water in, the retrofit kits are not water resistant.
  • Although we provide a mogul base for convenience in holding the Retrofit kit, if you are applying for rebates, do not use it, instead use just the bracket, otherwise the installation will not pass DLC inspection.
  • Connect the driver's output wires to the retrofit kit. Make sure that nothing will obstruct the fan blades.

* NOTES *
  • You may customize the mounting plate or bracket so it can be mounted into the fixture’s existing screw posts.
  • A plate to cover the driver to avoid touching the wires connections is needed.







STREET LIGHTS:
  • Remove existing ballast, bulb and reflector. Leave no electrical connections to the E26/E39 base.
  • Mount the LED driver in place of the ballast.
  • Fix the retrofit kit with the bracket, then adjust the retrofit head angle and position so that it provides the best lighting.
  • Connect the driver's output wires to the retrofit kit. Make sure that nothing will obstruct the fan blades.

Tip: The original mogul base was attached to the reflector when it was removed, customized plate is easy to install.




HIGH BAYS:
  • Remove existing ballast and bulb. Leave no electrical connections to the E26/E39 base.
  • Mount the LED driver in place of the ballast.
  • Although we provide a mogul base for convenience in holding the Retrofit kit, if you are applying for rebates, do not use it, instead use just the bracket, otherwise the installation will not pass DLC inspection.
  • Make sure nothing will obstruct the fan blades.

Tip: You may customize the mounting plate or bracket to mount the driver if needed.


* WARNING *
  • The unit is designed for several years use with minimum care. For Optimum performance, periodically clean the reflector and lens with a mild, non-abrasive, glass cleaner and a soft cloth. DO NOT use solvents or cleaners containing abrasive agents. When cleaning the fixture, make sure you have the power turned off and do not spray liquid cleaner directly onto the LED, socket or wiring.
  • Retrofit kits 180W and over require a lens cover, pictured below



180W-240W PC lens cover dimension:


300W-450W PC cover lens dimension:



5 YEAR WARRANTY POLICY
For Commercial LED Lamps and fixtures


This document sets forth the warranty policy of the LEDRadiant organization (‘LEDRadiant’) from which you (‘Purchaser’) purchase your commercial LED Lamps .

This policy is applicable only to LEDRadiant (‘Products’) described in the Warranty Certificate extended to the Purchaser along with the correlated invoice or the Certificate in the website page for the product being questioned.

This warranty policy is subject to the provisions as set forth herein and is subject to the terms and conditions as attached to this document (‘Warranty Terms and Conditions’) .

This warranty policy only applies if referred to in a sales agreement between LEDRadiant and the Purchaser and it will replace the standard warranty clause provided in the LEDRadiant general terms and conditions of sale.

Warranty period
5 Year. The warranty period starts on the date the products are delivered.
By default, purchaser receives above mentioned ‘standard warranty’.

On request, an ‘extended warranty’ or ‘customized project warranty’ can be agreed upon after evaluation of the specific application conditions. Extended warranty cost will be calculated and applied to the order.

Purchaser shall not rely upon any other information or documentation.

Within the warranty period, LEDRadiant will replace any defective bulb or fixture with equal or updated working model in the same conditions or better.

Summary Warranty Terms and Conditions (non-exhaustive)

This warranty policy is valid only for products sold in The United States of America.
Products have been purchased directly from a LEDRadiant (sales) organization.
Proof of purchase is available for inspection by LEDRadiant.
Products have been properly installed and operated in accordance with the manufacturer’s instructions.
• More than 10% of the LED chips are not properly working.
A LEDRadiant representative will have access to the defective Products.
If the Products or other parts become suspect, the representative shall have the right to invite other manufacturers’ representatives to evaluate the lighting systems.
Shipping and Labor costs for installation of the Products are not covered under this warranty.

This warranty is valid for order number:




By LEDRadiant

Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

RETROFITING UL LUMINAIRES
ONLINE CERTIFICATIONS DIRECTORY
IFAR.Guidelnfo
Light-emitting-diode Retrofit Luminaire Conversion Kits
[Luminaires and Fittings] Light-emitting-diode Retrofit Luminaire Conversion Kits

GENERAL

This category covers light-emitting-diode (LED) retrofit kits intended for field installation in certified luminaires and office-furnishing lights.

This category does not cover retrofit reflector kits and luminaire conversion lamps intended for direct replacement of existing lamps without the need for modification, rewiring or component replacement in the luminaire.

The retrofit kits consist of LED light sources, installation instructions, subassemblies, luminaire marking labels, and assembly aids (where appropriate) to facilitate the replacement of the existing light source in complete luminaires. The retrofit installation may require modifications to the luminaire in accordance with the installation instructions provided with the retrofit kits.

The LED retrofit kits have been investigated to determine that, when installed in accordance with the manufacturer's instructions, they do not adversely affect the operation of the luminaire. A luminaire that is modified so it can no longer accept the original lamp has a label provided by the retrofit kit manufacturer affixed to the luminaire where visible during relamping that indicates the luminaire has been modified and can no longer operate the originally-intended lamp(s).

LUMINAIRE MARKINGS

LED retrofit luminaire conversion kits that permit the insertion of the original lamp types are provided with a marking for installation by the kit installer on the retrofitted luminaire. This marking is visible during relamping and states, "This luminaire has been modified and can no longer operate the originally intended lamp," and additionally identifies the replacement LED lamp type/model to be used, together with the manufacturer's name and ordering information.

LED retrofit luminaire conversion kits using linear tubular LED lamp conversions are provided with a marking for installation by the kit installer visible during relamping that indicates in text or wiring diagram how the supply connections are made to the lampholders.

RELATED PRODUCTS

Retrofit reflector kits intended for installation on fluorescent luminaires are covered under Luminaire Conversions, Retrofit (IEUO).

Retrofit devices used to convert incandescent exit luminaires to fluorescent exit luminaires are covered under Exit Sign Conversion Kits (FWCF). LED light sources intended to replace fluorescent lamps where it is not necessary to modify the luminaire are covered under Lamps, Self-ballasted, Light-emitting-diode Type (OOLV).

ADDITIONAL INFORMATION

For additional information, see Luminaires and Fittings (HYXT) and Electrical Equipment for Use in Ordinary Locations (AALZ).

REQUIREMENTS

The basic requirements used to investigate products in this category are contained in UL Subject 1598C, "Outline of Investigation for Light-Emitting Diode (LED) Retrofit Luminaire Conversion Kits," in addition to ANSIIUL 1598, "Luminaires," ANSIIUL 153, "Portable Electric Luminaires," and/or ANSIIUL 1286, "Office Furnishings."

UL MARK

The Certification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number.

Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

RETROFITING UL LUMINAIRES

Additional Certification Markings

Products covered under this category are additionally marked with the following information:

LED RETROFIT LUMINAIRE CONVERSION


FOR USE ONLY WITH ( +)

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT

( +) PERMANENTLY CONNECTED LUMINAIRES, FLUORESCENT LUMINAIRES, INCANDESCENT LUMINAIRES, HID LUMINAIRES, OFFICE-FURNISHING LIGHTS and/or PORTABLE LUMINAIRES; or indicate the specific luminaire model(s) and luminaire manufacturer(s)

or

LED RETROFIT LUMINAIRE CONVERSION

FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT Alternate UL Mark

The Classification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Classification and Follow-Up Service. The Classification Mark for these products includes the UL symbol, the word "CLASSIFIED" above the UL symbol (as illustrated in the Introduction of this Directory), and the following additional information:

LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH ( +)

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT
Control No.

( +) PERMANENTLY-CONNECTED LUMINAIRES, FLUORESCENT LUMINAIRES, INCANDESCENT LUMINAIRES, HID LUMINAIRES, OFFICE-FURNISHING LIGHTS and/or PORTABLE LUMINAIRES; or indicate the specific luminaire model(s) and luminaire manufacturer(s)

or

LED RETROFIT LUMINAIRE CONVERSION

FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT
Control No.

* * * * * * * * * * * * * * * * * * * * * * * * *

UL, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental or consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Guide Information.

Last Updated on 2013-05-16

© 2014 UL LLC

When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " © 2014 UL LLC".

Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com
Product Tags

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Reviews

Customer Reviews

As always, these retrofits provide the necessary light while saving hundreds of dollars over new fixtures including installation. Review by Timothy J.
Rate
These retrofits produce an increase in the visible light over a 400 watt MH. They also cost less than new LED fixtures. Additionally, they cost less to have installed than a new LED fixture. Overall they save around $200 in comparison to a new LED fixture.
(Posted on 8/16/2017)
BRIGHT Review by JOHN M.
Rate
Very easy to install, and puts out some major light
(Posted on 4/24/2015)

Write Your Own Review

Only registered users can write reviews. Please, log in or register

FAQ

Site Seals

Advaith Starts
Advaith Ends