Electrical:
| Watts: | 63 |
| Operating Voltage: | 120-277 VAC |
| Operating Temperature: | -22° F to 113° F |
| Operating Humidity: | 10% to 70%RH |
| Power Factor (PF): | >92% |
| Power Supply Efficiency: | >92% |
Photometric:
| LED Luminous Flux (lm): | 2080 |
| CRI (ra): | >N/A |
| Color Temperature (Kelvin): | Amber 590nm |
| Lens type: | Polycarbonate |
| Expected Life: | 70,000 hrs. |
| L70: | 50,000 hrs. |
| Beam Angle: | Ask usº |
Mechanical:
| IP Rating: | IPn/a |
| Connector: | Wired |
| Base Type: | Hardwired |
| Heat Radiator: | Aluminum |
| Color: | Dark Bronze |
| Product Size: | 16.77 in diameter x 3.39 in H (lamp head only) |
| Package Size: | 19.09'' x 19.09'' x 9.45'' |
| Unit Gross Weight: | 13.6700 Lb |
Certifications:
| Safety Compliance: | cUL, UL |







615 N 21st Avenue, Hollywood, FL 33020, United States of America — Tel: +1 (844)533-7230
[email protected] — www.ledradiant.com
Amber LED Canopy Light for Covered Exterior Areas
A low-profile round head can keep the underside of an outdoor canopy visually simple while providing a distinct amber source. This amber LED canopy light is offered in Dark Bronze with a separately purchased surface-mount arrangement. Its 590–605nm wavelength makes it relevant to turtle-sensitive project specifications where the entire installation, including shielding and surrounding conditions, is reviewed for the intended site.
Consider the Covered Areas Between Buildings
Appropriate locations include covered hotel walkways, porte-cocheres, exterior pedestrian entrances, sheltered community paths, and outdoor covered parking. A ceiling-based arrangement can place illumination above circulation without adding a wall arm or pole. Review canopy construction, access for maintenance, surrounding windows, and adjacent sensitive areas. The fixture rating does not establish a particular mounting height, foot-candle level, spacing, or coverage area.
Configure the Light Output for the Plan
The lamp head provides selectable 63/53/33W settings, with 63W as the factory default. Maximum documented output is 2,080 lumens. Lower-power lumen values are not specified here, and the maximum should not be treated as the output of every setting. Select power in conjunction with the lighting layout and optical configuration rather than relying on wattage alone.
Keep Mounting and Accessories Separate
Surface-mount hardware and all accessories are sold separately. The head itself measures 16.77 inches in diameter and 3.39 inches deep. With the illustrated optional surface-mount assembly, overall height is 4.17 inches. Those assembly dimensions do not mean the pictured bracket is included with the lamp head. Have the installer check the selected mounting assembly, ceiling support, electrical provisions, and clearances before installation.
Choose Distribution and Controls Carefully
Type V distribution is standard; Type II, Type III, and Type IV configurations are available for different layouts. Confirm the configuration that matches the intended covered area. A half glare shield, photocell, motion sensor, and emergency battery are optional accessories. Purchase those components separately when the project requires them, and confirm their integration with the selected mounting and wiring arrangement.
The driver uses internal 0–10V continuous dimming, but its dimming connections are occupied and cannot be used for external dimmer control. This limitation is separate from the selectable wattage function. Electrical supply is 120–277VAC, 50/60Hz. The product has documented 10kV surge withstand ratings and power factor greater than 0.92. A 39.4-inch cord is supplied inside the housing and must be routed out during installation.
Review Construction and Service Conditions
The housing is powder-coated die-cast aluminum, with a heavy-duty polycarbonate lens over the optical assembly. The fixture is cULus listed for wet locations and has a documented ambient operating range from -22°F to 113°F. A five-year limited warranty applies. Use a qualified electrician and consider the actual exposure beneath the canopy. Wet-location listing does not imply submersible use or verify suitability for every corrosive environment, and an amber source alone does not certify the complete lighting installation.
We invite you to browse our selection. If you have any questions about our LED products, feel free to chat with us, message us on WhatsApp, or call us at 844-533-7230. We're happy to help!

Electrical:
| Watts: | 63 |
| Operating Voltage: | 120-277 VAC |
| Operating Temperature: | -22° F to 113° F |
| Operating Humidity: | 10% to 70%RH |
| Power Factor (PF): | >92% |
| Power Supply Efficiency: | >92% |
Photometric:
| LED Luminous Flux (lm): | 2080 |
| CRI (ra): | >N/A |
| Color Temperature (Kelvin): | Amber 590nm |
| Lens type: | Polycarbonate |
| Expected Life: | 70,000 hrs. |
| L70: | 50,000 hrs. |
| Beam Angle: | Ask usº |
Mechanical:
| IP Rating: | IPn/a |
| Connector: | Wired |
| Base Type: | Hardwired |
| Heat Radiator: | Aluminum |
| Color: | Dark Bronze |
| Product Size: | 16.77 in diameter x 3.39 in H (lamp head only) |
| Package Size: | 19.09'' x 19.09'' x 9.45'' |
| Unit Gross Weight: | 13.6700 Lb |
Certifications:
| Safety Compliance: | cUL, UL |







615 N 21st Avenue, Hollywood, FL 33020, United States of America — Tel: +1 (844)533-7230
[email protected] — www.ledradiant.com
Amber LED Canopy Light for Covered Exterior Areas
A low-profile round head can keep the underside of an outdoor canopy visually simple while providing a distinct amber source. This amber LED canopy light is offered in Dark Bronze with a separately purchased surface-mount arrangement. Its 590–605nm wavelength makes it relevant to turtle-sensitive project specifications where the entire installation, including shielding and surrounding conditions, is reviewed for the intended site.
Consider the Covered Areas Between Buildings
Appropriate locations include covered hotel walkways, porte-cocheres, exterior pedestrian entrances, sheltered community paths, and outdoor covered parking. A ceiling-based arrangement can place illumination above circulation without adding a wall arm or pole. Review canopy construction, access for maintenance, surrounding windows, and adjacent sensitive areas. The fixture rating does not establish a particular mounting height, foot-candle level, spacing, or coverage area.
Configure the Light Output for the Plan
The lamp head provides selectable 63/53/33W settings, with 63W as the factory default. Maximum documented output is 2,080 lumens. Lower-power lumen values are not specified here, and the maximum should not be treated as the output of every setting. Select power in conjunction with the lighting layout and optical configuration rather than relying on wattage alone.
Keep Mounting and Accessories Separate
Surface-mount hardware and all accessories are sold separately. The head itself measures 16.77 inches in diameter and 3.39 inches deep. With the illustrated optional surface-mount assembly, overall height is 4.17 inches. Those assembly dimensions do not mean the pictured bracket is included with the lamp head. Have the installer check the selected mounting assembly, ceiling support, electrical provisions, and clearances before installation.
Choose Distribution and Controls Carefully
Type V distribution is standard; Type II, Type III, and Type IV configurations are available for different layouts. Confirm the configuration that matches the intended covered area. A half glare shield, photocell, motion sensor, and emergency battery are optional accessories. Purchase those components separately when the project requires them, and confirm their integration with the selected mounting and wiring arrangement.
The driver uses internal 0–10V continuous dimming, but its dimming connections are occupied and cannot be used for external dimmer control. This limitation is separate from the selectable wattage function. Electrical supply is 120–277VAC, 50/60Hz. The product has documented 10kV surge withstand ratings and power factor greater than 0.92. A 39.4-inch cord is supplied inside the housing and must be routed out during installation.
Review Construction and Service Conditions
The housing is powder-coated die-cast aluminum, with a heavy-duty polycarbonate lens over the optical assembly. The fixture is cULus listed for wet locations and has a documented ambient operating range from -22°F to 113°F. A five-year limited warranty applies. Use a qualified electrician and consider the actual exposure beneath the canopy. Wet-location listing does not imply submersible use or verify suitability for every corrosive environment, and an amber source alone does not certify the complete lighting installation.
We invite you to browse our selection. If you have any questions about our LED products, feel free to chat with us, message us on WhatsApp, or call us at 844-533-7230. We're happy to help!