You have no items in your shopping cart.
No |
Wiring Diagram: 1.DO NOT MATE CONNECTOR UNTIL INSTALLATIONIS COMPLETE AND AC POWER IS SUPPLIED. 2.TEST ACCESSORY LEADS-OBSERVE PROPER POLARITY WIRING. Dimensions: Case- '' '' ''(mounting center-14.4'') 15 2.24 1.3 X X Listed for field installation-UL924 and CSA C22.2 NO.141 Features: UL Listed For field or factory installation Specifications: REV 09 15'' 2.24'' 1.3'' 1.73'' 14.4'' Constant output power (Auto sensing output Output LVLE Compliant Battery protections: over voltage protection, low voltage protection, RoHS compliant Weight 3.4 lbs(1.56kg) Dimensions 15''x2.17''x1.3'' (382mmx55mmx32mm) 2' (450mm) Flexible Conduit Ambient Temperature Rating 0°C to +50°C (32°F to 122°F) Recharge Time ≥24Hours Battery Charging Current 250mA Battery High-Temperature,Miantenance-Free Ni-MH battery 5 Years Life Expectancy Test Switch Charging Indicator Light Low Voltage,illuminated Test Switch / Full Warranty 5 Years Illumination Time 90 Minutes ≥ Output Power 20W max. Output Current and Voltage 416-800mA 25V 48V (Class 2) AC Input Power Rating 5.5W max. AC Input Current 100mA max. Universal Input Voltage 100-277Vac 50/60Hz Emergency LED Driver S E493915 R RoHS 382mm 55mm 365.7mm 44mm 44mm SWITCH BLACK WHITE LED DRIVER Driver + Driver - WHITE BLACK Battery Wiring EMERGENCY LED BLUE LED-(BLUE) LED ARRAY AC-L AC-N WHITE WHITE with Connector DRIVER WITH COMMON(RED) CHARGE INDICATOR(GRAY) TEST SWITCH(BLACK) MALFUNCTION(GREEN) KIT READY CHARGING INDICATOR TEST SWTCH Web:www.ledradiant.com Email:[email protected] Tel:+1844-533-7230 Emergency LED Driver The emergency driver can be used with most LED loads that have a rated voltage of 25-48Vdc.These emergency driver have been evaluated to and found compliant to UL 924.The the system must meet or exceed all Federal State and Local code requirements - , , . BLD-AM20D-480800 READ AND FOLLOW ALL SAFETY INSTRUCTIONS. NOTE When the dial switch code 1 and 2 turn off, the emergency : 25-48Vdc Emergency Power Power Voltage 20W 15W 1 2 - - - O N O N - 10W Do not join battery pack connecter until all other wiring is complete and AC power is on. Do not mount near gas or electric heaters. Do not let power supply cords touch hot surfaces. This LED Emergency Backup unit requires an un switched AC power source of 100 277Vac 50 60Hz The - - , / . Do not use outdoors. To prevent electrical shock only mate unit connector after installation is complete and before the , . The electrical rating of this product is 100 277Vac.Installer must confirm that there is 100 277Vac the - - . Before installing make certain the AC power to the fixture is off , . Risk of fire or electric shock.This LED Emergency Backup installation requires knowledge of luminaires electrical systems.If not qualifed do not attempt installation.Contact a qualifed electrician. , Risk of fire or electric shock.Luminaire wiring and electrical parts may be damaged when drilling for installation of LED Emergency Backup Check for enclosed wiring and components . . Dial switch code selection Applications Operation When using electrical equipment, basic safety precautions should always be followed including the following: Equipment should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized personnel. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. AC Operation AC power is present.The AC driver operates the LED load as designed.AC LED driver that : , . Emergency Operation When the AC power goes out the emergency pack detects the power outage and : , , , - . Manlfunction Mode:When the emergency driver internal circuit without fault and battery normal,The green SAVE THESE INSTRUCTIONS Web:www.ledradiant.com Email:[email protected] Tel:+1.844.533.7230 5 YEAR WARRANTY POLICY
For Commercial LED Lamps and fixtures
• This warranty policy is valid only for products sold in The United States of America.
• Products have been purchased directly from a LEDRadiant (sales) organization. • Proof of purchase is available for inspection by LEDRadiant. • Products have been properly installed and operated in accordance with the manufacturer’s instructions. • More than 10% of the LED chips are not properly working. • A LEDRadiant representative will have access to the defective Products. • If the Products or other parts become suspect, the representative shall have the right to invite other manufacturers’ representatives to evaluate the lighting systems. • Shipping and Labor costs for installation of the Products are not covered under this warranty. This warranty is valid for order number: By LEDRadiant Save the environment, your children and the planet
|
Rate |
---|
Rate |
---|
No |
Wiring Diagram: 1.DO NOT MATE CONNECTOR UNTIL INSTALLATIONIS COMPLETE AND AC POWER IS SUPPLIED. 2.TEST ACCESSORY LEADS-OBSERVE PROPER POLARITY WIRING. Dimensions: Case- '' '' ''(mounting center-14.4'') 15 2.24 1.3 X X Listed for field installation-UL924 and CSA C22.2 NO.141 Features: UL Listed For field or factory installation Specifications: REV 09 15'' 2.24'' 1.3'' 1.73'' 14.4'' Constant output power (Auto sensing output Output LVLE Compliant Battery protections: over voltage protection, low voltage protection, RoHS compliant Weight 3.4 lbs(1.56kg) Dimensions 15''x2.17''x1.3'' (382mmx55mmx32mm) 2' (450mm) Flexible Conduit Ambient Temperature Rating 0°C to +50°C (32°F to 122°F) Recharge Time ≥24Hours Battery Charging Current 250mA Battery High-Temperature,Miantenance-Free Ni-MH battery 5 Years Life Expectancy Test Switch Charging Indicator Light Low Voltage,illuminated Test Switch / Full Warranty 5 Years Illumination Time 90 Minutes ≥ Output Power 20W max. Output Current and Voltage 416-800mA 25V 48V (Class 2) AC Input Power Rating 5.5W max. AC Input Current 100mA max. Universal Input Voltage 100-277Vac 50/60Hz Emergency LED Driver S E493915 R RoHS 382mm 55mm 365.7mm 44mm 44mm SWITCH BLACK WHITE LED DRIVER Driver + Driver - WHITE BLACK Battery Wiring EMERGENCY LED BLUE LED-(BLUE) LED ARRAY AC-L AC-N WHITE WHITE with Connector DRIVER WITH COMMON(RED) CHARGE INDICATOR(GRAY) TEST SWITCH(BLACK) MALFUNCTION(GREEN) KIT READY CHARGING INDICATOR TEST SWTCH Web:www.ledradiant.com Email:[email protected] Tel:+1844-533-7230 Emergency LED Driver The emergency driver can be used with most LED loads that have a rated voltage of 25-48Vdc.These emergency driver have been evaluated to and found compliant to UL 924.The the system must meet or exceed all Federal State and Local code requirements - , , . BLD-AM20D-480800 READ AND FOLLOW ALL SAFETY INSTRUCTIONS. NOTE When the dial switch code 1 and 2 turn off, the emergency : 25-48Vdc Emergency Power Power Voltage 20W 15W 1 2 - - - O N O N - 10W Do not join battery pack connecter until all other wiring is complete and AC power is on. Do not mount near gas or electric heaters. Do not let power supply cords touch hot surfaces. This LED Emergency Backup unit requires an un switched AC power source of 100 277Vac 50 60Hz The - - , / . Do not use outdoors. To prevent electrical shock only mate unit connector after installation is complete and before the , . The electrical rating of this product is 100 277Vac.Installer must confirm that there is 100 277Vac the - - . Before installing make certain the AC power to the fixture is off , . Risk of fire or electric shock.This LED Emergency Backup installation requires knowledge of luminaires electrical systems.If not qualifed do not attempt installation.Contact a qualifed electrician. , Risk of fire or electric shock.Luminaire wiring and electrical parts may be damaged when drilling for installation of LED Emergency Backup Check for enclosed wiring and components . . Dial switch code selection Applications Operation When using electrical equipment, basic safety precautions should always be followed including the following: Equipment should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized personnel. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. AC Operation AC power is present.The AC driver operates the LED load as designed.AC LED driver that : , . Emergency Operation When the AC power goes out the emergency pack detects the power outage and : , , , - . Manlfunction Mode:When the emergency driver internal circuit without fault and battery normal,The green SAVE THESE INSTRUCTIONS Web:www.ledradiant.com Email:[email protected] Tel:+1.844.533.7230 5 YEAR WARRANTY POLICY
For Commercial LED Lamps and fixtures
• This warranty policy is valid only for products sold in The United States of America.
• Products have been purchased directly from a LEDRadiant (sales) organization. • Proof of purchase is available for inspection by LEDRadiant. • Products have been properly installed and operated in accordance with the manufacturer’s instructions. • More than 10% of the LED chips are not properly working. • A LEDRadiant representative will have access to the defective Products. • If the Products or other parts become suspect, the representative shall have the right to invite other manufacturers’ representatives to evaluate the lighting systems. • Shipping and Labor costs for installation of the Products are not covered under this warranty. This warranty is valid for order number: By LEDRadiant Save the environment, your children and the planet
|
Rate |
---|
Rate |
---|