(844) 533-7230
Welcome to LEDRADIANT, your LED lighting source
Shopping Cart - 0 Item

You have no items in your shopping cart.

 

  • Led Corn Bulb 75W 9900 Lm 5000K IP64 E39

Led Corn Bulb 75W 9900 Lm 5000K IP64 E39

Availability: Backordered


This 75 Watt LED Corn Bulb equals up to a 300 watts HID bulb. The replacement will save up to 75% in electricity, labor and parts, as lifespan is over 15 years. The bulb is IP64, built with fire retardant plastics and easy to clean. It can be used in sealed IP65 fixtures and in wet locations. Estimated annual ROI is about 40%.

Click here to see other Corn Bulb Lights.

Availability: In stock

Regular Price: $92.00

Special Price $77.95

  • Buy 10 for $76.39 each and save 3%
  • Buy 25 for $75.61 each and save 4%
  • Buy 50 for $74.83 each and save 5%
  • Buy 100 for $74.05 each and save 6%



Replace halogen, metal halide, incandescent or HPS with LED corn bulbs
LED corn bulbs will be equivalent twice the power of CFLs, 10 times incandescent and 5 times Metal Halide or HPS
Compact Fluorescent Metal Halide or HPS LED Corn Bulb
50W100W 20 Watts
80W150W 30 Watts
100W175W 40 Watts
125W250W 50 Watts
175W300W 60 Watts
200W400W 100 Watts
250W600W 120 Watts
 750W 150 Watts
No
WIRING DIAGRAM
LED Corn Cob Bulbs

HID & HPS REPLACEMENT

Important note: The lamp holder must be disconnected from the wiring to the ballast and ignitor, verify that voltage does not exceeds 277VAC.
Flashing bulb indicates that the Protection Circuit triggered: Disconnect inmediately, check voltage and wiring! otherwise the LED Corn Cob Bulb will be ruined and the warranty voided.

1. Turn off the mains and power to the system.
2. Remove the HID or HPS bulbs.
3. Cut connections from lamp holder and remove the ballast(s) and the ignitor(s).
4. Connect the live wire to the center connection of the lamp holder.
5. Connect the neutral wire to the external connection of the lamp holder.
6. Insert and screw in the LED Corn Cob Bulb.
7. Turn on the mains.The fixture is ready to be used.

Save the environment, your children and the planet
615 North 21st Ave., Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

DIAGRAMA DE CABLEADO
LED Choclo o LED Mazorca

REEMPLAZO DE LÁMPARAS DE DESCARGA GASEOSA

Nota Importante: El zócalo del bulbo debe ser desconectado completamente del balasto y el arrancador. Verificar que el voltaje no exceda 277VAC.
El encendido intermitente indica que se disparó el circuito de protección: Desconectar inmediatamente, verificar el voltaje y las conexiones, de lo contrario la lámpara de LED Choclo o Mazorca se arruinará y la garantia será invalidada.

1.- Cortar el suministro general al aparato.
2.- Remover las lámparas de vidrio.
3.- Cortar las conexiones y retirar balasto(s) y arrancador(es).
4.- Conectar el cable vivo de Ia alimentación directamente al centro del zócalo.
5.- Conectar el cable neutro (común) de Ia alimentación directamente al exterior del zócalo.
6.- Inserte y enrosque la lámpara de estado sólido.
7.- Conecte la potencia. El artefacto está listo para ser utilizado.

Salva el medio ambiente, tus hijos y el planeta!
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

5 YEAR WARRANTY POLICY
For Commercial LED Lamps and fixtures


This document sets forth the warranty policy of the LEDRadiant organization (‘LEDRadiant’) from which you (‘Purchaser’) purchase your commercial LED Lamps .

This policy is applicable only to LEDRadiant (‘Products’) described in the Warranty Certificate extended to the Purchaser along with the correlated invoice or the Certificate in the website page for the product being questioned.

This warranty policy is subject to the provisions as set forth herein and is subject to the terms and conditions as attached to this document (‘Warranty Terms and Conditions’) .

This warranty policy only applies if referred to in a sales agreement between LEDRadiant and the Purchaser and it will replace the standard warranty clause provided in the LEDRadiant general terms and conditions of sale.

Warranty period
5 Year. The warranty period starts on the date the products are delivered.
By default, purchaser receives above mentioned ‘standard warranty’.

On request, an ‘extended warranty’ or ‘customized project warranty’ can be agreed upon after evaluation of the specific application conditions. Extended warranty cost will be calculated and applied to the order.

Purchaser shall not rely upon any other information or documentation.

Within the warranty period, LEDRadiant will replace any defective bulb or fixture with equal or updated working model in the same conditions or better.

Summary Warranty Terms and Conditions (non-exhaustive)

This warranty policy is valid only for products sold in The United States of America.
Products have been purchased directly from a LEDRadiant (sales) organization.
Proof of purchase is available for inspection by LEDRadiant.
Products have been properly installed and operated in accordance with the manufacturer’s instructions.
• More than 10% of the LED chips are not properly working.
A LEDRadiant representative will have access to the defective Products.
If the Products or other parts become suspect, the representative shall have the right to invite other manufacturers’ representatives to evaluate the lighting systems.
Shipping and Labor costs for installation of the Products are not covered under this warranty.

This warranty is valid for order number:




By LEDRadiant

Save the environment, your children and the planet
615 N 21st Ave., Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

RETROFITING UL LUMINAIRES
ONLINE CERTIFICATIONS DIRECTORY
IFAR.Guidelnfo
Light-emitting-diode Retrofit Luminaire Conversion Kits
[Luminaires and Fittings] Light-emitting-diode Retrofit Luminaire Conversion Kits

GENERAL

This category covers light-emitting-diode (LED) retrofit kits intended for field installation in certified luminaires and office-furnishing lights.

This category does not cover retrofit reflector kits and luminaire conversion lamps intended for direct replacement of existing lamps without the need for modification, rewiring or component replacement in the luminaire.

The retrofit kits consist of LED light sources, installation instructions, subassemblies, luminaire marking labels, and assembly aids (where appropriate) to facilitate the replacement of the existing light source in complete luminaires. The retrofit installation may require modifications to the luminaire in accordance with the installation instructions provided with the retrofit kits.

The LED retrofit kits have been investigated to determine that, when installed in accordance with the manufacturer's instructions, they do not adversely affect the operation of the luminaire. A luminaire that is modified so it can no longer accept the original lamp has a label provided by the retrofit kit manufacturer affixed to the luminaire where visible during relamping that indicates the luminaire has been modified and can no longer operate the originally-intended lamp(s).

LUMINAIRE MARKINGS

LED retrofit luminaire conversion kits that permit the insertion of the original lamp types are provided with a marking for installation by the kit installer on the retrofitted luminaire. This marking is visible during relamping and states, "This luminaire has been modified and can no longer operate the originally intended lamp," and additionally identifies the replacement LED lamp type/model to be used, together with the manufacturer's name and ordering information.

LED retrofit luminaire conversion kits using linear tubular LED lamp conversions are provided with a marking for installation by the kit installer visible during relamping that indicates in text or wiring diagram how the supply connections are made to the lampholders.

RELATED PRODUCTS

Retrofit reflector kits intended for installation on fluorescent luminaires are covered under Luminaire Conversions, Retrofit (IEUO).

Retrofit devices used to convert incandescent exit luminaires to fluorescent exit luminaires are covered under Exit Sign Conversion Kits (FWCF). LED light sources intended to replace fluorescent lamps where it is not necessary to modify the luminaire are covered under Lamps, Self-ballasted, Light-emitting-diode Type (OOLV).

ADDITIONAL INFORMATION

For additional information, see Luminaires and Fittings (HYXT) and Electrical Equipment for Use in Ordinary Locations (AALZ).

REQUIREMENTS

The basic requirements used to investigate products in this category are contained in UL Subject 1598C, "Outline of Investigation for Light-Emitting Diode (LED) Retrofit Luminaire Conversion Kits," in addition to ANSIIUL 1598, "Luminaires," ANSIIUL 153, "Portable Electric Luminaires," and/or ANSIIUL 1286, "Office Furnishings."

UL MARK

The Certification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number.

Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

RETROFITING UL LUMINAIRES

Additional Certification Markings

Products covered under this category are additionally marked with the following information:

LED RETROFIT LUMINAIRE CONVERSION


FOR USE ONLY WITH ( +)

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT

( +) PERMANENTLY CONNECTED LUMINAIRES, FLUORESCENT LUMINAIRES, INCANDESCENT LUMINAIRES, HID LUMINAIRES, OFFICE-FURNISHING LIGHTS and/or PORTABLE LUMINAIRES; or indicate the specific luminaire model(s) and luminaire manufacturer(s)

or

LED RETROFIT LUMINAIRE CONVERSION

FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT Alternate UL Mark

The Classification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Classification and Follow-Up Service. The Classification Mark for these products includes the UL symbol, the word "CLASSIFIED" above the UL symbol (as illustrated in the Introduction of this Directory), and the following additional information:

LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH ( +)

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT
Control No.

( +) PERMANENTLY-CONNECTED LUMINAIRES, FLUORESCENT LUMINAIRES, INCANDESCENT LUMINAIRES, HID LUMINAIRES, OFFICE-FURNISHING LIGHTS and/or PORTABLE LUMINAIRES; or indicate the specific luminaire model(s) and luminaire manufacturer(s)

or

LED RETROFIT LUMINAIRE CONVERSION

FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT
Control No.

* * * * * * * * * * * * * * * * * * * * * * * * *

UL, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental or consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Guide Information.

Last Updated on 2013-05-16

© 2014 UL LLC

When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " © 2014 UL LLC".

Save the environment, your children and the planet
615 North 21st Ave., Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Customer Reviews

solid, excellent choice Review by Harry
Rate
ot only does it save a significant amount on electricity costs, but the IP64 rating ensures durability even in harsh weather conditions.
(Posted on 1/17/2024)
good Review by Henry
Rate
excellent it's a versatile and efficient lighting solution.
(Posted on 9/23/2023)

Write Your Own Review

You're reviewing: Led Corn Bulb 75W 9900 Lm 5000K IP64 E39

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Rate
Product Description



Replace halogen, metal halide, incandescent or HPS with LED corn bulbs
LED corn bulbs will be equivalent twice the power of CFLs, 10 times incandescent and 5 times Metal Halide or HPS
Compact Fluorescent Metal Halide or HPS LED Corn Bulb
50W100W 20 Watts
80W150W 30 Watts
100W175W 40 Watts
125W250W 50 Watts
175W300W 60 Watts
200W400W 100 Watts
250W600W 120 Watts
 750W 150 Watts
Additional Information
No
WIRING DIAGRAM
LED Corn Cob Bulbs

HID & HPS REPLACEMENT

Important note: The lamp holder must be disconnected from the wiring to the ballast and ignitor, verify that voltage does not exceeds 277VAC.
Flashing bulb indicates that the Protection Circuit triggered: Disconnect inmediately, check voltage and wiring! otherwise the LED Corn Cob Bulb will be ruined and the warranty voided.

1. Turn off the mains and power to the system.
2. Remove the HID or HPS bulbs.
3. Cut connections from lamp holder and remove the ballast(s) and the ignitor(s).
4. Connect the live wire to the center connection of the lamp holder.
5. Connect the neutral wire to the external connection of the lamp holder.
6. Insert and screw in the LED Corn Cob Bulb.
7. Turn on the mains.The fixture is ready to be used.

Save the environment, your children and the planet
615 North 21st Ave., Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

DIAGRAMA DE CABLEADO
LED Choclo o LED Mazorca

REEMPLAZO DE LÁMPARAS DE DESCARGA GASEOSA

Nota Importante: El zócalo del bulbo debe ser desconectado completamente del balasto y el arrancador. Verificar que el voltaje no exceda 277VAC.
El encendido intermitente indica que se disparó el circuito de protección: Desconectar inmediatamente, verificar el voltaje y las conexiones, de lo contrario la lámpara de LED Choclo o Mazorca se arruinará y la garantia será invalidada.

1.- Cortar el suministro general al aparato.
2.- Remover las lámparas de vidrio.
3.- Cortar las conexiones y retirar balasto(s) y arrancador(es).
4.- Conectar el cable vivo de Ia alimentación directamente al centro del zócalo.
5.- Conectar el cable neutro (común) de Ia alimentación directamente al exterior del zócalo.
6.- Inserte y enrosque la lámpara de estado sólido.
7.- Conecte la potencia. El artefacto está listo para ser utilizado.

Salva el medio ambiente, tus hijos y el planeta!
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

5 YEAR WARRANTY POLICY
For Commercial LED Lamps and fixtures


This document sets forth the warranty policy of the LEDRadiant organization (‘LEDRadiant’) from which you (‘Purchaser’) purchase your commercial LED Lamps .

This policy is applicable only to LEDRadiant (‘Products’) described in the Warranty Certificate extended to the Purchaser along with the correlated invoice or the Certificate in the website page for the product being questioned.

This warranty policy is subject to the provisions as set forth herein and is subject to the terms and conditions as attached to this document (‘Warranty Terms and Conditions’) .

This warranty policy only applies if referred to in a sales agreement between LEDRadiant and the Purchaser and it will replace the standard warranty clause provided in the LEDRadiant general terms and conditions of sale.

Warranty period
5 Year. The warranty period starts on the date the products are delivered.
By default, purchaser receives above mentioned ‘standard warranty’.

On request, an ‘extended warranty’ or ‘customized project warranty’ can be agreed upon after evaluation of the specific application conditions. Extended warranty cost will be calculated and applied to the order.

Purchaser shall not rely upon any other information or documentation.

Within the warranty period, LEDRadiant will replace any defective bulb or fixture with equal or updated working model in the same conditions or better.

Summary Warranty Terms and Conditions (non-exhaustive)

This warranty policy is valid only for products sold in The United States of America.
Products have been purchased directly from a LEDRadiant (sales) organization.
Proof of purchase is available for inspection by LEDRadiant.
Products have been properly installed and operated in accordance with the manufacturer’s instructions.
• More than 10% of the LED chips are not properly working.
A LEDRadiant representative will have access to the defective Products.
If the Products or other parts become suspect, the representative shall have the right to invite other manufacturers’ representatives to evaluate the lighting systems.
Shipping and Labor costs for installation of the Products are not covered under this warranty.

This warranty is valid for order number:




By LEDRadiant

Save the environment, your children and the planet
615 N 21st Ave., Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

RETROFITING UL LUMINAIRES
ONLINE CERTIFICATIONS DIRECTORY
IFAR.Guidelnfo
Light-emitting-diode Retrofit Luminaire Conversion Kits
[Luminaires and Fittings] Light-emitting-diode Retrofit Luminaire Conversion Kits

GENERAL

This category covers light-emitting-diode (LED) retrofit kits intended for field installation in certified luminaires and office-furnishing lights.

This category does not cover retrofit reflector kits and luminaire conversion lamps intended for direct replacement of existing lamps without the need for modification, rewiring or component replacement in the luminaire.

The retrofit kits consist of LED light sources, installation instructions, subassemblies, luminaire marking labels, and assembly aids (where appropriate) to facilitate the replacement of the existing light source in complete luminaires. The retrofit installation may require modifications to the luminaire in accordance with the installation instructions provided with the retrofit kits.

The LED retrofit kits have been investigated to determine that, when installed in accordance with the manufacturer's instructions, they do not adversely affect the operation of the luminaire. A luminaire that is modified so it can no longer accept the original lamp has a label provided by the retrofit kit manufacturer affixed to the luminaire where visible during relamping that indicates the luminaire has been modified and can no longer operate the originally-intended lamp(s).

LUMINAIRE MARKINGS

LED retrofit luminaire conversion kits that permit the insertion of the original lamp types are provided with a marking for installation by the kit installer on the retrofitted luminaire. This marking is visible during relamping and states, "This luminaire has been modified and can no longer operate the originally intended lamp," and additionally identifies the replacement LED lamp type/model to be used, together with the manufacturer's name and ordering information.

LED retrofit luminaire conversion kits using linear tubular LED lamp conversions are provided with a marking for installation by the kit installer visible during relamping that indicates in text or wiring diagram how the supply connections are made to the lampholders.

RELATED PRODUCTS

Retrofit reflector kits intended for installation on fluorescent luminaires are covered under Luminaire Conversions, Retrofit (IEUO).

Retrofit devices used to convert incandescent exit luminaires to fluorescent exit luminaires are covered under Exit Sign Conversion Kits (FWCF). LED light sources intended to replace fluorescent lamps where it is not necessary to modify the luminaire are covered under Lamps, Self-ballasted, Light-emitting-diode Type (OOLV).

ADDITIONAL INFORMATION

For additional information, see Luminaires and Fittings (HYXT) and Electrical Equipment for Use in Ordinary Locations (AALZ).

REQUIREMENTS

The basic requirements used to investigate products in this category are contained in UL Subject 1598C, "Outline of Investigation for Light-Emitting Diode (LED) Retrofit Luminaire Conversion Kits," in addition to ANSIIUL 1598, "Luminaires," ANSIIUL 153, "Portable Electric Luminaires," and/or ANSIIUL 1286, "Office Furnishings."

UL MARK

The Certification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number.

Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

RETROFITING UL LUMINAIRES

Additional Certification Markings

Products covered under this category are additionally marked with the following information:

LED RETROFIT LUMINAIRE CONVERSION


FOR USE ONLY WITH ( +)

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT

( +) PERMANENTLY CONNECTED LUMINAIRES, FLUORESCENT LUMINAIRES, INCANDESCENT LUMINAIRES, HID LUMINAIRES, OFFICE-FURNISHING LIGHTS and/or PORTABLE LUMINAIRES; or indicate the specific luminaire model(s) and luminaire manufacturer(s)

or

LED RETROFIT LUMINAIRE CONVERSION

FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT Alternate UL Mark

The Classification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Classification and Follow-Up Service. The Classification Mark for these products includes the UL symbol, the word "CLASSIFIED" above the UL symbol (as illustrated in the Introduction of this Directory), and the following additional information:

LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH ( +)

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT
Control No.

( +) PERMANENTLY-CONNECTED LUMINAIRES, FLUORESCENT LUMINAIRES, INCANDESCENT LUMINAIRES, HID LUMINAIRES, OFFICE-FURNISHING LIGHTS and/or PORTABLE LUMINAIRES; or indicate the specific luminaire model(s) and luminaire manufacturer(s)

or

LED RETROFIT LUMINAIRE CONVERSION

FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT
Control No.

* * * * * * * * * * * * * * * * * * * * * * * * *

UL, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental or consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Guide Information.

Last Updated on 2013-05-16

© 2014 UL LLC

When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " © 2014 UL LLC".

Save the environment, your children and the planet
615 North 21st Ave., Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com
Product Tags

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Reviews

Customer Reviews

solid, excellent choice Review by Harry
Rate
ot only does it save a significant amount on electricity costs, but the IP64 rating ensures durability even in harsh weather conditions.
(Posted on 1/17/2024)
good Review by Henry
Rate
excellent it's a versatile and efficient lighting solution.
(Posted on 9/23/2023)

Write Your Own Review

You're reviewing: Led Corn Bulb 75W 9900 Lm 5000K IP64 E39

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Rate
FAQ

Site Seals

Advaith Starts
Advaith Ends