  • 40W Full Cut-Off LED Wall Pack Fixture: 4500Lm 5000K IP65

40W Full Cut-Off LED Wall Pack Fixture: 4500Lm 5000K IP65

Availability: In stock


This 40W LED Wall Pack Full-Cut-Off equals a 175 Watt HID bulb. Head can be titlted up to 90 degrees to illuminate the required area without affecting neighbors. Saves more than 75% in electricity and hundreds in unnecessary bulb replacements. Lifespan is over 15 years. LEDRADIANT Wall Packs are waterproof. Estimated annual ROI is about 60%.



Click here to see other Wallpacks.

Availability: In stock

Regular Price: $95.00

Special Price $80.75

  • Buy 10 for $76.71 each and save 6%
  • Buy 25 for $74.29 each and save 8%
  • Buy 50 for $72.67 each and save 11%
  • Buy 100 for $71.06 each and save 12%



PHEKUR8H
CUTOFF INSTALLATION GUIDE
(WFM-FZC-40450-5Y)

PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION

- To prevent personal injury or product damage only licensed electricians should install.
- To avoid electric shock or component damage disconnect power before attempting installation or servicing.
- This product must be installed in accordance with the national electric cede (NEG) and all applicable federal, state and local electric codes and safety standards.
- Disconnect product and allow cooling prior to servicing.
- Any alteration or modification of this product is expressly forbidden as it may cause serious personal injury, death, property damage and/or product malfunction.
- To prevent product malfunction and/or electrical shock this product must be properly grounded.
- This luminaire is designed to operate in ambient temperatures ranging from -30°C to 45°C and to be horizontally mounted with the LEDs facing down.
- Wall mount only.


MOUNTING TO A WALL

1. Orient Wall Mount Box such that TOP is pointing up.
2. Feed supply wires through Wall Mount Box Gasket into Wall Mount Box through Silicone Wiring Plug, if not using conduit/ connectors.
3. Secure Wall Mount Box to a sturdy mounting surface. Use appropriate mounting hardware such as lag bolts and anchors with washers suitable for the mounting surface. A Leveling Bubble is provided to level fixture.
4. Silicone around the edge of Wall Mount Box Gasket and/ or junction box.
S. Check that Gasket is fully sealed.
6. Slide the stainless steel Tether from the fixture into the Key Hole Slot for hands free wiring.
7. Wire the fixture using UL listed wire connectors according to NEC and local codes.
8. Place wired fixture over the Wall Mount Box and tighten the Top Screws. Then tighten the Lower Screws.
9. Tighten Close up Plugs and apply weatherproof silicone sealant to all unused conduit entry points.





ON-OFF WIRING


Universal voltage driver permits operation at 120V to 277VAC, 50 or 60 Hz except fixtures factory ordered with a 120V swivel photocell (/PCS) or 277V swivel photocell (/PCS2) or 480V swivel photocell (/PCS4).Units ordered with (/480V) suffix are 480V.


1. Connect the BLACK fixture lead to the (+) LINE supply lead.
2. Connect the WHITE fixture lead to the (-) COMMON supply lead.
3. Connect the bare copper Ground wire from fixture to supply ground.



0-10V DIMMABLE WIRING


Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. For 0-10V Dimming, follow the wiring directions as in fig. 2.


1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply lead.
3. Connect the GROUND wire from fixture to supply ground. Do NOT connect the GROUND of the dimming fixture to the output
4. Connect the purple fixture lead to the (V+) DIM lead.
5. Connect the gray fixture lead to the (V-) DIM lead.
6. Cap the yellow fixture lead, if present. Do NOT connect.

PHOTOCELL INSTALLATION


Photocell may be installed in the field. Apply weatherproof silicone sealant to all plugs and unused conduit entries.


1. Remove close up plug on top of the wall mounting box.
2. Install photocell and wire as per diagram.
3. Use photocell rated for your supply voltage.



TROUBLESHOOTING


1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
2. Is the fixture grounded properly?
3. Be sure the photocell, if used, is functioning properly.


CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.


1. Clean glass lens with non-abrasive glass cleaning solution.
2. Do not open the fixture to clean the LED. Do not touch the LED.


Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

5 YEAR WARRANTY POLICY
For Commercial LED Lamps and fixtures


This document sets forth the warranty policy of the LEDRadiant organization (‘LEDRadiant’) from which you (‘Purchaser’) purchase your commercial LED Lamps .

This policy is applicable only to LEDRadiant (‘Products’) described in the Warranty Certificate extended to the Purchaser along with the correlated invoice or the Certificate in the website page for the product being questioned.

This warranty policy is subject to the provisions as set forth herein and is subject to the terms and conditions as attached to this document (‘Warranty Terms and Conditions’) .

This warranty policy only applies if referred to in a sales agreement between LEDRadiant and the Purchaser and it will replace the standard warranty clause provided in the LEDRadiant general terms and conditions of sale.

Warranty period
5 Year. The warranty period starts on the date the products are delivered.
By default, purchaser receives above mentioned ‘standard warranty’.

On request, an ‘extended warranty’ or ‘customized project warranty’ can be agreed upon after evaluation of the specific application conditions. Extended warranty cost will be calculated and applied to the order.

Purchaser shall not rely upon any other information or documentation.

Within the warranty period, LEDRadiant will replace any defective bulb or fixture with equal or updated working model in the same conditions or better.

Summary Warranty Terms and Conditions (non-exhaustive)

This warranty policy is valid only for products sold in The United States of America.
Products have been purchased directly from a LEDRadiant (sales) organization.
Proof of purchase is available for inspection by LEDRadiant.
Products have been properly installed and operated in accordance with the manufacturer’s instructions.
• More than 10% of the LED chips are not properly working.
A LEDRadiant representative will have access to the defective Products.
If the Products or other parts become suspect, the representative shall have the right to invite other manufacturers’ representatives to evaluate the lighting systems.
Shipping and Labor costs for installation of the Products are not covered under this warranty.

This warranty is valid for order number:




By LEDRadiant

Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

RETROFITING UL LUMINAIRES
ONLINE CERTIFICATIONS DIRECTORY
IFAR.Guidelnfo
Light-emitting-diode Retrofit Luminaire Conversion Kits
[Luminaires and Fittings] Light-emitting-diode Retrofit Luminaire Conversion Kits

GENERAL

This category covers light-emitting-diode (LED) retrofit kits intended for field installation in certified luminaires and office-furnishing lights.

This category does not cover retrofit reflector kits and luminaire conversion lamps intended for direct replacement of existing lamps without the need for modification, rewiring or component replacement in the luminaire.

The retrofit kits consist of LED light sources, installation instructions, subassemblies, luminaire marking labels, and assembly aids (where appropriate) to facilitate the replacement of the existing light source in complete luminaires. The retrofit installation may require modifications to the luminaire in accordance with the installation instructions provided with the retrofit kits.

The LED retrofit kits have been investigated to determine that, when installed in accordance with the manufacturer's instructions, they do not adversely affect the operation of the luminaire. A luminaire that is modified so it can no longer accept the original lamp has a label provided by the retrofit kit manufacturer affixed to the luminaire where visible during relamping that indicates the luminaire has been modified and can no longer operate the originally-intended lamp(s).

LUMINAIRE MARKINGS

LED retrofit luminaire conversion kits that permit the insertion of the original lamp types are provided with a marking for installation by the kit installer on the retrofitted luminaire. This marking is visible during relamping and states, "This luminaire has been modified and can no longer operate the originally intended lamp," and additionally identifies the replacement LED lamp type/model to be used, together with the manufacturer's name and ordering information.

LED retrofit luminaire conversion kits using linear tubular LED lamp conversions are provided with a marking for installation by the kit installer visible during relamping that indicates in text or wiring diagram how the supply connections are made to the lampholders.

RELATED PRODUCTS

Retrofit reflector kits intended for installation on fluorescent luminaires are covered under Luminaire Conversions, Retrofit (IEUO).

Retrofit devices used to convert incandescent exit luminaires to fluorescent exit luminaires are covered under Exit Sign Conversion Kits (FWCF). LED light sources intended to replace fluorescent lamps where it is not necessary to modify the luminaire are covered under Lamps, Self-ballasted, Light-emitting-diode Type (OOLV).

ADDITIONAL INFORMATION

For additional information, see Luminaires and Fittings (HYXT) and Electrical Equipment for Use in Ordinary Locations (AALZ).

REQUIREMENTS

The basic requirements used to investigate products in this category are contained in UL Subject 1598C, "Outline of Investigation for Light-Emitting Diode (LED) Retrofit Luminaire Conversion Kits," in addition to ANSIIUL 1598, "Luminaires," ANSIIUL 153, "Portable Electric Luminaires," and/or ANSIIUL 1286, "Office Furnishings."

UL MARK

The Certification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number.

Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

RETROFITING UL LUMINAIRES

Additional Certification Markings

Products covered under this category are additionally marked with the following information:

LED RETROFIT LUMINAIRE CONVERSION


FOR USE ONLY WITH ( +)

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT

( +) PERMANENTLY CONNECTED LUMINAIRES, FLUORESCENT LUMINAIRES, INCANDESCENT LUMINAIRES, HID LUMINAIRES, OFFICE-FURNISHING LIGHTS and/or PORTABLE LUMINAIRES; or indicate the specific luminaire model(s) and luminaire manufacturer(s)

or

LED RETROFIT LUMINAIRE CONVERSION

FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT Alternate UL Mark

The Classification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Classification and Follow-Up Service. The Classification Mark for these products includes the UL symbol, the word "CLASSIFIED" above the UL symbol (as illustrated in the Introduction of this Directory), and the following additional information:

LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH ( +)

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT
Control No.

( +) PERMANENTLY-CONNECTED LUMINAIRES, FLUORESCENT LUMINAIRES, INCANDESCENT LUMINAIRES, HID LUMINAIRES, OFFICE-FURNISHING LIGHTS and/or PORTABLE LUMINAIRES; or indicate the specific luminaire model(s) and luminaire manufacturer(s)

or

LED RETROFIT LUMINAIRE CONVERSION

FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT
Control No.

* * * * * * * * * * * * * * * * * * * * * * * * *

UL, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental or consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Guide Information.

Last Updated on 2013-05-16

© 2014 UL LLC

When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " © 2014 UL LLC".

Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Customer Reviews

Easy install with included splice box Review by Juan P
Rate
Easy to install when need no extra junction box with mc-cable. Head adjusts to desired angle and easy adjustment.
(Posted on 10/28/2020)
Modern Review by Felix O.
Rate
We retrofitted our corporate building with these wall packs that are very refined and matched the modern construction.
(Posted on 1/29/2020)
Elegant and smart fixtures, very refined Review by Jim B.
Rate
These full cut off wallpack fixtures match perfectly with the smart building, so elegant and refined, exactly what my clients wanted, and the photocell is a plus.
(Posted on 1/19/2020)
No street lights, add these! Review by Grover C.
Rate
Once I completed the installation of the first one, the real test came when it got dark. All I can say is OMG. These lights are brighter than the 175W that I used before. Where we live, there are no street lights so these wall packs enlighten the whole neighborhood.
(Posted on 1/12/2020)
Safer building Review by Norris C.
Rate
I manage a business park so I am changing out the old dated lighting 175 w with 40w led wall packs, the parking lots are very well lit now, making it much safer for my tenants
(Posted on 9/25/2019)

Write Your Own Review

You're reviewing: 40W Full Cut-Off LED Wall Pack Fixture: 4500Lm 5000K IP65

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Rate
Product Description



Additional Information
PHEKUR8H
CUTOFF INSTALLATION GUIDE
(WFM-FZC-40450-5Y)

PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION

- To prevent personal injury or product damage only licensed electricians should install.
- To avoid electric shock or component damage disconnect power before attempting installation or servicing.
- This product must be installed in accordance with the national electric cede (NEG) and all applicable federal, state and local electric codes and safety standards.
- Disconnect product and allow cooling prior to servicing.
- Any alteration or modification of this product is expressly forbidden as it may cause serious personal injury, death, property damage and/or product malfunction.
- To prevent product malfunction and/or electrical shock this product must be properly grounded.
- This luminaire is designed to operate in ambient temperatures ranging from -30°C to 45°C and to be horizontally mounted with the LEDs facing down.
- Wall mount only.


MOUNTING TO A WALL

1. Orient Wall Mount Box such that TOP is pointing up.
2. Feed supply wires through Wall Mount Box Gasket into Wall Mount Box through Silicone Wiring Plug, if not using conduit/ connectors.
3. Secure Wall Mount Box to a sturdy mounting surface. Use appropriate mounting hardware such as lag bolts and anchors with washers suitable for the mounting surface. A Leveling Bubble is provided to level fixture.
4. Silicone around the edge of Wall Mount Box Gasket and/ or junction box.
S. Check that Gasket is fully sealed.
6. Slide the stainless steel Tether from the fixture into the Key Hole Slot for hands free wiring.
7. Wire the fixture using UL listed wire connectors according to NEC and local codes.
8. Place wired fixture over the Wall Mount Box and tighten the Top Screws. Then tighten the Lower Screws.
9. Tighten Close up Plugs and apply weatherproof silicone sealant to all unused conduit entry points.





ON-OFF WIRING


Universal voltage driver permits operation at 120V to 277VAC, 50 or 60 Hz except fixtures factory ordered with a 120V swivel photocell (/PCS) or 277V swivel photocell (/PCS2) or 480V swivel photocell (/PCS4).Units ordered with (/480V) suffix are 480V.


1. Connect the BLACK fixture lead to the (+) LINE supply lead.
2. Connect the WHITE fixture lead to the (-) COMMON supply lead.
3. Connect the bare copper Ground wire from fixture to supply ground.



0-10V DIMMABLE WIRING


Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. For 0-10V Dimming, follow the wiring directions as in fig. 2.


1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply lead.
3. Connect the GROUND wire from fixture to supply ground. Do NOT connect the GROUND of the dimming fixture to the output
4. Connect the purple fixture lead to the (V+) DIM lead.
5. Connect the gray fixture lead to the (V-) DIM lead.
6. Cap the yellow fixture lead, if present. Do NOT connect.

PHOTOCELL INSTALLATION


Photocell may be installed in the field. Apply weatherproof silicone sealant to all plugs and unused conduit entries.


1. Remove close up plug on top of the wall mounting box.
2. Install photocell and wire as per diagram.
3. Use photocell rated for your supply voltage.



TROUBLESHOOTING


1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
2. Is the fixture grounded properly?
3. Be sure the photocell, if used, is functioning properly.


CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.


1. Clean glass lens with non-abrasive glass cleaning solution.
2. Do not open the fixture to clean the LED. Do not touch the LED.


Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

5 YEAR WARRANTY POLICY
For Commercial LED Lamps and fixtures


This document sets forth the warranty policy of the LEDRadiant organization (‘LEDRadiant’) from which you (‘Purchaser’) purchase your commercial LED Lamps .

This policy is applicable only to LEDRadiant (‘Products’) described in the Warranty Certificate extended to the Purchaser along with the correlated invoice or the Certificate in the website page for the product being questioned.

This warranty policy is subject to the provisions as set forth herein and is subject to the terms and conditions as attached to this document (‘Warranty Terms and Conditions’) .

This warranty policy only applies if referred to in a sales agreement between LEDRadiant and the Purchaser and it will replace the standard warranty clause provided in the LEDRadiant general terms and conditions of sale.

Warranty period
5 Year. The warranty period starts on the date the products are delivered.
By default, purchaser receives above mentioned ‘standard warranty’.

On request, an ‘extended warranty’ or ‘customized project warranty’ can be agreed upon after evaluation of the specific application conditions. Extended warranty cost will be calculated and applied to the order.

Purchaser shall not rely upon any other information or documentation.

Within the warranty period, LEDRadiant will replace any defective bulb or fixture with equal or updated working model in the same conditions or better.

Summary Warranty Terms and Conditions (non-exhaustive)

This warranty policy is valid only for products sold in The United States of America.
Products have been purchased directly from a LEDRadiant (sales) organization.
Proof of purchase is available for inspection by LEDRadiant.
Products have been properly installed and operated in accordance with the manufacturer’s instructions.
• More than 10% of the LED chips are not properly working.
A LEDRadiant representative will have access to the defective Products.
If the Products or other parts become suspect, the representative shall have the right to invite other manufacturers’ representatives to evaluate the lighting systems.
Shipping and Labor costs for installation of the Products are not covered under this warranty.

This warranty is valid for order number:




By LEDRadiant

Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

RETROFITING UL LUMINAIRES
ONLINE CERTIFICATIONS DIRECTORY
IFAR.Guidelnfo
Light-emitting-diode Retrofit Luminaire Conversion Kits
[Luminaires and Fittings] Light-emitting-diode Retrofit Luminaire Conversion Kits

GENERAL

This category covers light-emitting-diode (LED) retrofit kits intended for field installation in certified luminaires and office-furnishing lights.

This category does not cover retrofit reflector kits and luminaire conversion lamps intended for direct replacement of existing lamps without the need for modification, rewiring or component replacement in the luminaire.

The retrofit kits consist of LED light sources, installation instructions, subassemblies, luminaire marking labels, and assembly aids (where appropriate) to facilitate the replacement of the existing light source in complete luminaires. The retrofit installation may require modifications to the luminaire in accordance with the installation instructions provided with the retrofit kits.

The LED retrofit kits have been investigated to determine that, when installed in accordance with the manufacturer's instructions, they do not adversely affect the operation of the luminaire. A luminaire that is modified so it can no longer accept the original lamp has a label provided by the retrofit kit manufacturer affixed to the luminaire where visible during relamping that indicates the luminaire has been modified and can no longer operate the originally-intended lamp(s).

LUMINAIRE MARKINGS

LED retrofit luminaire conversion kits that permit the insertion of the original lamp types are provided with a marking for installation by the kit installer on the retrofitted luminaire. This marking is visible during relamping and states, "This luminaire has been modified and can no longer operate the originally intended lamp," and additionally identifies the replacement LED lamp type/model to be used, together with the manufacturer's name and ordering information.

LED retrofit luminaire conversion kits using linear tubular LED lamp conversions are provided with a marking for installation by the kit installer visible during relamping that indicates in text or wiring diagram how the supply connections are made to the lampholders.

RELATED PRODUCTS

Retrofit reflector kits intended for installation on fluorescent luminaires are covered under Luminaire Conversions, Retrofit (IEUO).

Retrofit devices used to convert incandescent exit luminaires to fluorescent exit luminaires are covered under Exit Sign Conversion Kits (FWCF). LED light sources intended to replace fluorescent lamps where it is not necessary to modify the luminaire are covered under Lamps, Self-ballasted, Light-emitting-diode Type (OOLV).

ADDITIONAL INFORMATION

For additional information, see Luminaires and Fittings (HYXT) and Electrical Equipment for Use in Ordinary Locations (AALZ).

REQUIREMENTS

The basic requirements used to investigate products in this category are contained in UL Subject 1598C, "Outline of Investigation for Light-Emitting Diode (LED) Retrofit Luminaire Conversion Kits," in addition to ANSIIUL 1598, "Luminaires," ANSIIUL 153, "Portable Electric Luminaires," and/or ANSIIUL 1286, "Office Furnishings."

UL MARK

The Certification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number.

Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com

RETROFITING UL LUMINAIRES

Additional Certification Markings

Products covered under this category are additionally marked with the following information:

LED RETROFIT LUMINAIRE CONVERSION


FOR USE ONLY WITH ( +)

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT

( +) PERMANENTLY CONNECTED LUMINAIRES, FLUORESCENT LUMINAIRES, INCANDESCENT LUMINAIRES, HID LUMINAIRES, OFFICE-FURNISHING LIGHTS and/or PORTABLE LUMINAIRES; or indicate the specific luminaire model(s) and luminaire manufacturer(s)

or

LED RETROFIT LUMINAIRE CONVERSION

FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT Alternate UL Mark

The Classification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Classification and Follow-Up Service. The Classification Mark for these products includes the UL symbol, the word "CLASSIFIED" above the UL symbol (as illustrated in the Introduction of this Directory), and the following additional information:

LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH ( +)

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT
Control No.

( +) PERMANENTLY-CONNECTED LUMINAIRES, FLUORESCENT LUMINAIRES, INCANDESCENT LUMINAIRES, HID LUMINAIRES, OFFICE-FURNISHING LIGHTS and/or PORTABLE LUMINAIRES; or indicate the specific luminaire model(s) and luminaire manufacturer(s)

or

LED RETROFIT LUMINAIRE CONVERSION

FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED

IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT
Control No.

* * * * * * * * * * * * * * * * * * * * * * * * *

UL, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental or consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Guide Information.

Last Updated on 2013-05-16

© 2014 UL LLC

When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification.

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product.

permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " © 2014 UL LLC".

Save the environment, your children and the planet
500 North Dixie Hwy, #8, Hollywood, FL 33020 – (844).533.7230
[email protected] www.ledradiant.com
Product Tags

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Reviews

Customer Reviews

Easy install with included splice box Review by Juan P
Rate
Easy to install when need no extra junction box with mc-cable. Head adjusts to desired angle and easy adjustment.
(Posted on 10/28/2020)
Modern Review by Felix O.
Rate
We retrofitted our corporate building with these wall packs that are very refined and matched the modern construction.
(Posted on 1/29/2020)
Elegant and smart fixtures, very refined Review by Jim B.
Rate
These full cut off wallpack fixtures match perfectly with the smart building, so elegant and refined, exactly what my clients wanted, and the photocell is a plus.
(Posted on 1/19/2020)
No street lights, add these! Review by Grover C.
Rate
Once I completed the installation of the first one, the real test came when it got dark. All I can say is OMG. These lights are brighter than the 175W that I used before. Where we live, there are no street lights so these wall packs enlighten the whole neighborhood.
(Posted on 1/12/2020)
Safer building Review by Norris C.
Rate
I manage a business park so I am changing out the old dated lighting 175 w with 40w led wall packs, the parking lots are very well lit now, making it much safer for my tenants
(Posted on 9/25/2019)

Write Your Own Review

You're reviewing: 40W Full Cut-Off LED Wall Pack Fixture: 4500Lm 5000K IP65

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Rate
FAQ

Site Seals

Advaith Starts
Advaith Ends